
A320 Systems · 108 questions in this category · sample below
Avionics ventilation system indications may be found on which ECAM page(s)?
Explanation: Avionics ventilation VENT/INLET/EXTRACT indications are found specifically on the ECAM CAB PRESS page, in the ventilation controls & indicators section — not on the BLEED page or the cruise page.
Air Cond / Pressurization - Ventilation Controls & Indicators
Which statement is correct regarding illumination of the amber AFT ISOL VALVE fault light?
Explanation: The AFT ISOL VALVE FAULT light, with its ECAM caution, comes on amber when either the inlet or outlet isolation valve disagrees with its selected (switch) position — it doesn't itself close anything or indicate a fan stoppage.
Air Cond / Pressurization - Cargo Controls & Indicators
Pack controller, primary channel failure.
Explanation: If a pack controller's primary channel fails, the secondary computer takes over as backup, but regulation is no longer optimized — pack flow is fixed at the previous setting.
Air Cond / Pressurization - System Operation Under Failure Condition
When landing elevation is set to AUTO, the landing elevation is sent to the controller from:
Explanation: When LDG ELEV is set to AUTO, the pressurization controller uses landing elevation data from the FMGS to build its pressure schedule.
Air Cond / Pressurization - Controls & Indicators (LDG ELEV knob)
How many outflow valves are there?
Explanation: There's a single outflow valve — but its assembly carries both inward- and outward-opening flaps linked to the actuator, giving it one valve with two doors.
Air Cond / Pressurization - Main Components (Outflow Valve)
In flight with pressure controller 1 in use, if it fails:
Explanation: If pressure controller 1 fails in flight, the system automatically transfers to controller 2 — no manual selection is required, since a transfer also happens automatically whenever the operating system fails.
Air Cond / Pressurization - Pressurization System Operation (Automatic Mode)
In normal flight in closed circuit configuration, the avionics ventilation system controls the temperature of the cooling air by:
Explanation: In normal flight (closed-circuit configuration), the avionics ventilation system controls cooling-air temperature by passing it through a skin heat exchanger.
Air Cond / Pressurization - Ventilation (Avionics Ventilation)
In case of trim air system fault (zone controller primary channel failure), the secondary channel of the zone
Explanation: With the zone controller's primary channel failed, the secondary channel takes over as backup and controls the zones to a fixed 24°C.
Air Cond / Pressurization - System Operation Under Failure Condition
This is a small sample. The full A320 Systems bank has 934 FCOM-backed questions, available in Study, Quiz and Exam mode with progress tracking that syncs across your devices.
Open AvBuddy — sign in free