A320 Systems · 73 questions in this category · sample below
Which communication and navigation radios are operational in the Emergency Electrical Configuration with the EMER GEN powering the system?
Explanation: The QRH's "ELEC EMER CONFIG SYS REMAINING" table, for the EMER GEN RUNNING column, lists VHF 1, HF 1, RMP 1, and both ACPs as NORM, and VOR and MMR (the ILS/GPS receiver) as "N°1 only" — matching ACP 1&2, VHF 1, HF, RMP 1, VOR 1, and ILS 1 exactly.
Electrical Abnormal Procedures - ELEC EMER CONFIG SYS REMAINING
An AC ESS FEED switch located on the overhead panel shifts the power source for the AC ESS bus from:
Explanation: In NORMAL, the AC ESS bus is fed from AC BUS 1. Selecting ALTN (or the automatic switching logic kicking in if AC BUS 1 is lost) shifts that feed to AC BUS 2.
Electrical - Controls & Indicators (AC ESS FEED)
How many times can you reset a circuit breaker?
Explanation: This reflects the general operating philosophy around circuit breakers as protective devices rather than switches — a reset is done once, and only when a procedure specifically authorizes it, not as a routine troubleshooting step. The extracted FCOM text doesn't state this as a single numbered rule verbatim, so treat the precise wording with some caution even though the underlying principle is standard.
Electrical - General / Description
If a TR fails:
Explanation: The FCOM's TR-fault distribution table confirms this: if TR 1 fails, TR 2 automatically takes over supplying DC BUS 1 (in addition to its own DC BUS 2), while the ESS TR takes over the DC ESS BUS — the same pattern applies symmetrically if TR 2 fails instead.
Electrical - General / Description (Distribution Table)
While operating on Emergency Electrical Power with the landing gear lowered which of the following statements is correct?
Explanation: Below 100 kt, the DC BAT BUS automatically reconnects to the batteries, and on the ground with only the batteries powering the emergency network, APU start is only available once speed drops below that same 100 kt threshold.
Electrical - General / Description (emergency generation network)
Which flight control computer will be inoperative with gear extension while in the Emergency Electrical Configuration?
Explanation:
If AC Bus 1 fails the AC ESS bus is supplied by:
Explanation: The FCOM confirms AC BUS 2 can supply the AC ESS BUS via the AC ESS feed contactor — so if AC BUS 1 is lost, the AC ESS bus transfers to being fed by AC BUS 2 instead.
Electrical - Controls & Indicators (AC ESS FEED)
Having started the APU, how can you get the APU generator to power the electrical system?
Explanation: External power outranks the APU generator in the priority order, so even with the APU generator switched on, it won't actually connect while external power is still supplying — pushing the EXT PWR pushbutton to disconnect ground power is what lets the (lower-priority) APU generator take over.
Electrical - General / Description
This is a small sample. The full A320 Systems bank has 934 FCOM-backed questions, available in Study, Quiz and Exam mode with progress tracking that syncs across your devices.